Bolt Grade Chart โ SAE, ASTM & ISO Grades, Strength Ratings and Head Markings
Start with the mark on the head. The identification tree below routes you to the right standard system before you read a strength table, because the same looking number can mean different things in SAE, ISO and ASTM documents.
Identification tree ยท tap a marking
8.8 / 10.9 / 12.9
Metric property class under ISO 898-1. The first number times 100 is minimum tensile strength in MPa; the second number times ten is the yield ratio as a percentage of tensile. Class 10.9 therefore promises at least 1000 MPa tensile and 900 MPa yield.
Bolt Grade Systems Overview
A bolt grade is a promise made by a standard. It tells the minimum strength the manufacturer must achieve in testing and, usually, how that promise is marked on the head. Three systems dominate the bolts you will meet: SAE J429 for imperial machine bolts, ISO 898-1 for metric property classes, and a family of ASTM product specifications for structural, stud and specialty fasteners.
The SAE system uses ordinal numbers: Grade 2, Grade 5 and Grade 8. Higher means stronger, and the exact tensile, yield and proof values come from J429 tables. The ISO system uses a two-part property class whose digits encode the numbers directly, which is why 8.8 can be decoded without opening the standard. ASTM specifications are product-based: A307 describes a low-carbon bolt, F3125 covers structural bolt grades, and A193 B7 describes an alloy-steel stud for elevated temperature.
These systems overlap in strength but not in requirements. A metric class 8.8 bolt and an SAE Grade 5 bolt sit in a similar strength band; a class 10.9 and Grade 8 sit in another. That does not make them interchangeable, because proof load, ductility, head geometry, nut matching and marking rules differ. The homepage of this site already gives the torque and preload implications of grade choice; this page concentrates on identification and the standard definitions behind the marks.
What this page does not repeat
The homepage grade section already publishes a strength chart, a preload target ladder and an answer to the strongest-grade question. Those conclusions are not duplicated here. This is an identification and standards reference, not a second copy of the same comparison.
SAE Bolt Grades Chart
Minimum tensile and yield strengths from the site's shared grade data, which follows SAE J429 for imperial grades. Values are converted from ksi at 6.894757 MPa per ksi and rounded to whole units.
| Grade | Standard | Tensile min | Yield min | Typical head mark |
|---|---|---|---|---|
| SAE Grade 2 | SAE J429 | 74 ksi / 510 MPa | 57 ksi / 393 MPa | None or two lines |
| SAE Grade 5 / ASTM A325 | SAE J429 | 120 ksi / 827 MPa | 92 ksi / 634 MPa | Three radial lines |
| SAE Grade 8 | SAE J429 | 150 ksi / 1034 MPa | 130 ksi / 896 MPa | Six radial lines |
Grade 2 is the everyday low-strength hardware grade; Grade 5 is the general automotive and machinery workhorse; Grade 8 is the high-strength choice for heavy equipment. Head markings are the conventional radial-line patterns in SAE J429; confirm against the current standard and the manufacturer's certificate for safety-critical hardware.
Metric Bolt Property Classes Chart
ISO 898-1 property classes encode their own strength. The first number times 100 is the minimum ultimate tensile strength in MPa; the second number divided by ten is the ratio of yield to tensile. The table lists the resulting minimums for the most common classes.
| Class | Tensile min | Yield min | Head mark | Application band |
|---|---|---|---|---|
| Class 8.8 | 800 MPa | 640 MPa | 8.8 | Metric structural workhorse |
| Class 10.9 | 1040 MPa | 940 MPa | 10.9 | Heavy equipment and high-strength joints |
| Class 12.9 | 1220 MPa | 1100 MPa | 12.9 | Maximum common commercial class |
Lower metric classes exist for general hardware, and stainless property classes use a different designation scheme. Always read the full callout: the digits promise minimums by specification, not the measured strength of an individual bolt.
ASTM Structural Bolt Grades
Structural bolts are specified by product standard rather than by an SAE ordinal. The table shows how the familiar names relate to the current ASTM F3125/F3125M system and what each family is used for.
| Designation | Standard family | Strength level | Where it belongs |
|---|---|---|---|
| A307 Grade A | ASTM A307 | 60 ksi minimum tensile | Light structural and anchor work |
| A325 / F3125 Gr A325 | ASTM F3125/F3125M | 120 ksi (105 ksi over 1 in), historical A325 level | Structural steel bearing-type and slip-critical connections |
| A490 / F3125 Gr A490 | ASTM F3125/F3125M | 150 ksi class | High-strength structural connections; no hot-dip galvanizing |
| A193 B7 | ASTM A193 | Alloy steel, quenched and tempered | Studs for elevated temperature and pressure service |
| F1852 / F2280 | ASTM F3125/F3125M | Twist-off assembly grades | Tension control structural assemblies |
A325 and A490 were separate historical ASTM specifications; F3125/F3125M consolidated the structural bolt grades under one document. Old drawings still use the former names. Verify the edition and grade callout in the project specification rather than assuming that every occurrence of a historic name carries identical current requirements.
Limit of visual identification
A marking tells you what a bolt is supposed to be. It cannot prove the batch passed testing, and an unmarked head is not a grade. Use certified hardware for critical connections.
Bolt Head Markings Identification
Markings fall into three visual families. Numeric property classes appear as two digits with a dot, defined by ISO 898-1. SAE grades use radial lines on the head, with three lines for Grade 5 and six for Grade 8 under J429. ASTM product grades are stamped as letters and numbers such as A307, A325, A490 or B7, sometimes with a manufacturer identifier alongside them.
Read the mark before reading a strength table. A bolt whose head shows six radial lines is in a different standard family from one stamped 10.9 even if their strengths are close. Symbol markings and manufacturer logos can sit next to the grade mark; the grade is the part defined by the standard, not the logo.
| Grade / class | Typical marking | Family | Identification note |
|---|---|---|---|
| SAE Grade 2 | Typically unmarked, sometimes two radial lines | Low-strength general hardware | Verify with certificate if unmarked |
| SAE Grade 5 | Three radial lines | Automotive and machinery general use | Strength level near ISO class 8.8 |
| SAE Grade 8 | Six radial lines | Heavy equipment and critical imperial joints | Closer to ISO class 10.9 |
| ISO 8.8 | 8.8 stamped on the head | Metric structural workhorse | 800 MPa tensile, 640 MPa yield |
| ISO 10.9 | 10.9 stamped on the head | High-strength metric assemblies | 1040 MPa tensile, 940 MPa yield |
| ISO 12.9 | 12.9 stamped on the head | Maximum common commercial metric class | 1220 MPa tensile, 1100 MPa yield |
| ASTM A307 | A307 or maker mark; low strength | Light structural and anchor applications | 60 ksi minimum tensile for Grade A |
| ASTM F3125 A325 | A325 or F3125 Grade A325 marking | Structural steel connections | 120/105 ksi historical strength level |
| ASTM F3125 A490 | A490 or F3125 Grade A490 marking | High-strength structural connections | 150 ksi class; do not galvanize |
| ASTM A193 B7 | B7 marking on studs | High-temperature and pressure service | Alloy steel, quenched and tempered |
Head stamps wear, corrode and can be obscured by paint. When the mark is incomplete, do not infer a grade from diameter, finish or application. Replace the fastener with traceable hardware or verify it through certificate records.
Strength Comparison and Approximate Equivalence
The useful comparison is by strength band, not by exact equality. Class 8.8 at 800 MPa tensile sits near SAE Grade 5 at 120 ksi (827 MPa). Class 10.9 at 1040 MPa sits near Grade 8 at 150 ksi (1034 MPa). A490 is also a 150 ksi class. These are minimum specification values in consistent units, not measured batch results.
Proof load is the comparison that matters most for tightening. It sits below yield and is the stress a bolt survives without measurable permanent stretch. Two bolts with similar tensile strength can carry different proof loads, which is why a cross-system substitution can change the clamp force a given torque produces. The homepage explains the 75 percent and 90 percent preload targets that build on proof and yield; this page stops at the grade definitions.
Grade 5 versus Grade 8
Grade 8 raises tensile from 120 ksi to 150 ksi and yield from 92 ksi to 130 ksi. The gain comes with reduced ductility, so Grade 8 is not automatically the safer choice in a joint that needs plastic redistribution.
8.8 versus 10.9
Class 10.9 lifts tensile from 800 MPa to 1040 MPa and yield from 640 MPa to 940 MPa. That extra preload capacity is useful in high-strength joints but leaves less margin against over-tightening and hydrogen-related issues.
Choosing the Correct Bolt Grade
Start with the design. The joint's load, connection type, environment and code determine the acceptable grade; the chart helps you recognise that grade once it arrives on site. Choosing the highest number on the shelf is not a design method. High-strength bolts are less ductile, more sensitive to coating restrictions and more demanding on matching nuts and washers.
Match the nut and washer to the bolt grade. A high-strength bolt in a low-strength tapped hole can strip the internal thread before the bolt reaches its own capacity, which is the failure mode the thread engagement calculator addresses. In structural work the bolt, nut and washer are specified as a system; substituting one component can void the connection's qualification.
Consider the service environment. Elevated temperature calls for grades designed for it, such as ASTM A193 B7 studs. Corrosive exposure may require a coating, and the coating must be compatible with the grade: A490-class fasteners must not be hot-dip galvanized. Fatigue-prone joints favour details that reduce stress concentration rather than simply a higher strength number.
Grade selection is not connection design. Once a grade is identified, use the bolt tension calculator or the shear calculator to check capacity. Neither replaces bearing, tear-out, fatigue or code checks.
Coatings and Strength Data Notes
Zinc plating and hot-dip galvanizing do not change the strength grade printed on a bolt. They change the friction at the threads and under the head, which changes the relationship between wrench torque and achieved preload. A dry torque value applied to a lubricated or plated bolt can overstress it, so a coating change should trigger a fresh look at the tightening specification.
Some coatings interact with high-strength grades in more serious ways. Hydrogen embrittlement is the reason ASTM A490 fasteners must not be hot-dip galvanized. Always check the standard and the manufacturer's data sheet for the specific grade and coating pair before specifying it.
The numbers in this chart are minimums from the specifications, not typical test values. A real batch of class 8.8 bolts often measures above 800 MPa, but designing against the typical value would quietly remove the safety margin the grade mark promises. Units are stated throughout: MPa for metric strength and ksi for imperial strength, converted at 6.894757 MPa per ksi.
Identify, Then Calculate
This bolt grade chart is the upstream reference for the site's calculators. Once the mark is decoded, the bolt torque spec chart gives starting torque values and the thread pitch and stress area chart gives the area each strength check uses. The homepage applies grades to preload targets, and the full library sits on the guides hub.
Bolt Grade Chart FAQ
Markings, standards, strength definitions and cross-system comparisons.
What is a bolt grade chart?
How do I identify a bolt grade from head markings?
What does 8.8 mean on a bolt?
What is the difference between Grade 5 and Grade 8 bolts?
Are metric 8.8 and SAE Grade 5 the same?
What is the difference between A325, A490 and ASTM F3125?
What is proof load and why is it different from tensile strength?
What does ASTM A307 cover?
Do coatings change a bolt's grade?
Can I choose a bolt grade by strength alone?
Related Inner Pages
Bolt Torque Spec Chart
Grade-indexed torque values by diameter.
Thread Pitch & Stress Area
The area used by every strength calculation.
Bolt Tension Calculator
Grade strength as an input to tensile capacity.
Bolt Shear Calculator
Grade strength as an input to shear capacity.
Tension Control Bolts
Structural twist-off grades F1852 and F2280.
Thread Engagement Calculator
Matching bolt strength to the tapped material.
Sources and scope. Strength values follow ISO 898-1 for metric property classes, SAE J429 for imperial grades and ASTM A307 / F3125 / A193 product specifications, as implemented in the site's shared bolt data. Head-marking patterns are conventional descriptions from those standards; confirm against the current edition and manufacturer certification for critical hardware. ksi to MPa uses 6.894757 MPa per ksi.
Author & update. Bolt Calculatorengineering content team ยท Last updated 2026-11-23 ยท Data current to 2026-11-23. This chart is a reference for identification; it does not certify a bolt or replace a connection design reviewed by a qualified engineer.