Bolt Tension Calculator — Tensile Capacity & Combined Shear + Tension Check

Enter the bolt, the axial load and the moment share. The calculator resolves the tensile stress area, compares demand with capacity, and runs the combined shear-plus-tension interaction under both AISC and Eurocode conventions.

Input Parameters

Diameter, grade, loads and interaction basis.

Units
Bolt Sizenominal diameter
Thread Serieschanges the stress area
Grade / Material
External Tensiondirect axial load
kN
Moment Tension Shareextra pull per bolt from overturning moment
kN
Bolt Countbolts sharing the load
pcs
Safety Factordesign factor on capacitySF = 2
Shear Load Vper bolt, before interaction
kN
Code Basisinteraction convention

FAIL — 458.3% utilized

Demand 26.00 kN against allowable 5.67 kN. Remaining margin 20.33 kN.

Tensile Capacity Chain

Resolved threadp = 0.8 mm
Tensile stress area As14.18 mm²
Grade Fu / Fy800 / 640 MPa
Ultimate tension Fu × As11.35 kN
Allowable tension (SF 2)5.67 kN
Applied tension per bolt26.00 kN
Utilization458.3%
Bolts sharing load1

Combined Shear + Tension

Shear per bolt12.00 kN
AISC tension ratio tr2.943
AISC shear ratio vr1.809
AISC J3.7 interaction4.551
EC3 Ft,Rd8.17 kN
EC3 Fv,Rd5.45 kN
EC3 interaction4.477
Basis displayedAISC 360-16

AISC uses φ = 0.75, Fnt = 0.75Fu and Fnv = 0.563Fu (threads excluded); the shear coefficient drops to 8/9 once vr ≥ 0.2. Eurocode uses Ft,Rd = 0.9fubAs/1.25 and Fv,Ed/Fv,Rd + Ft,Ed/(1.4Ft,Rd) ≤ 1.0.

Preliminary reference only. This tool reports bolt-level tension and interaction ratios. It does not replace a connection design: prying action, bearing, tear-out, slip criticality, fatigue and code load factors must be checked by a qualified engineer against the governing specification.
Derivation

The Tension Check, Step by Step

The five steps below are the exact operations the calculator performs. Each step is written with the default M12 class 8.8 example so you can reproduce the numbers on paper and confirm the tool before trusting a different bolt.

01

Step 01 — Resolve the tensile stress area

For M12 coarse, the standard pitch is 1.75 mm. Substituting into As = 0.7854 × (12 − 0.9382 × 1.75)² gives 0.7854 × (10.358)² = 84.27 mm². This is the effective section that carries axial load through the threads, not the 113.1 mm² shank circle. If the fine-series selector is chosen, M12 × 1.25 raises As to about 92.1 mm², roughly a nine percent gain for the same nominal diameter.

02

Step 02 — Turn external load into per-bolt demand

The default inputs carry 20 kN of direct axial tension and 6 kN of additional pull from an overturning moment, with one bolt sharing the load. Demand is (20 + 6) / 1 = 26 kN, or 26,000 N. For a group of four bolts the same input divides to 6.5 kN per bolt. The moment share you type here should already have been distributed to the bolt being checked; the moment section below explains the elastic distribution used for that step.

03

Step 03 — Compute ultimate and allowable capacity

Class 8.8 has a specified minimum ultimate tensile strength of 800 MPa and a yield of 640 MPa. Ultimate tension is Fu × As = 800 × 84.27 = 67,416 N = 67.4 kN. At the default safety factor of 2.0, the allowable tension is 67,416 / 2 = 33,708 N = 33.7 kN. Notice that the safety factor divides capacity here; multiplying the load by the same factor instead is algebraically identical for the utilization ratio but changes how you report the margin.

04

Step 04 — Express demand as utilization

Utilization is 26,000 / 33,708 = 0.771, displayed as 77.1 percent and marked PASS. The remaining margin is 7,708 N or 7.7 kN. Raising the direct load to 30 kN pushes utilization to about 107 percent and flips the result to FAIL while every other input stays the same. That sensitivity is the reason the tool prints the full chain rather than only a verdict.

05

Step 05 — Add the combined-action check

With 12 kN of shear on the same bolt, AISC-style design strengths are φRn(t) = 0.75 × 0.75 × 800 × 113.1 = 37.9 kN and φRn(v) = 0.75 × 0.563 × 800 × 113.1 = 38.2 kN. The ratios are tr = 26/37.9 = 0.686 and vr = 12/38.2 = 0.314. Because vr exceeds 0.2, the J3.7 interaction is 0.686 + (8/9) × 0.314 = 0.965, still below 1.0. The Eurocode ratio on the same inputs is about 0.752.

Tip

Keep one unit system from input to output. MPa is N/mm², so stress in MPa multiplied by area in mm² returns force in newtons directly.

Unit warning

Entering 26 instead of 26,000 N in Step 04, or forgetting the ×1000 that converts kN, understates demand by three orders of magnitude. The tool converts for you; a hand calculation does not.

Do not

Do not use the nominal shank area for the tension check. At M12 it is 113.1 mm² against 84.27 mm² of stress area, a 34 percent overstatement of capacity.

Threaded steel bolt and nut on a workshop bench, viewed end-on to show the threaded sectionAxial tension acts on the threaded sectionPhoto: Unsplash

What breaks in a tensile test?

Not the flat root circle. A threaded rod pulls apart along a helical surface that cuts across several thread turns. The tensile stress area is an empirical effective section chosen to reproduce that failure load, which is why the formula blends the pitch and minor diameters instead of using either alone.

Why the Threaded Section Sets the Tension Limit

Four different areas appear in bolt calculations and mixing them is the most common source of a wrong answer. The nominal area is a label. The shank area carries bearing and, when threads are excluded, shear. The root circle is where fatigue cracks start. The tensile stress area As is the one that carries axial tension through the threaded portion, and it sits between the root and shank circles.

For coarse metric series As runs about 78 to 88 percent of the shank area, converging toward the higher end as diameter grows. Unified threads behave the same way. The reason is geometric: the thread roots cut material away, but the helical load path spreads force across multiple turns, so the failure section is larger than the flat minor circle and smaller than the uncut shank.

A fine series increases As slightly. M10 coarse at 1.5 mm pitch gives about 58.0 mm²; M10 × 1.25 fine gives about 61.2 mm². The gain is real but small compared with stepping up one nominal size, which is why fine thread is chosen more often for vibration resistance and short engagement lengths than for raw strength. The thread pitch and stress area chart on this site publishes the same As values used in the calculator, so a lookup and a calculation agree.

The exact formulas

As = 0.7854 × (d − 0.9382 × p)²   metric

As = 0.7854 × (D − 0.9743/n)²   unified

d and D are nominal diameter in millimetres, p is metric pitch in millimetres and n is unified threads per inch. The constants come from the ISO 68-1 basic 60-degree thread form and ASME B1.1. They are also the constants used by the site's thread pitch chart, so the two resources cannot drift apart.

Allowable Tension, Proof Load and the 90 Percent Question

Three numbers surround any discussion of bolt tension: proof load, yield strength and ultimate tensile strength. Proof is the maximum stress a bolt survives in a test without measurable permanent set. Yield is where permanent stretch begins. Ultimate is where it breaks. They are ordered proof below yield below ultimate, and each answers a different engineering question.

The homepage's preload guidance targets roughly 75 percent of proof or yield for a reusable joint and up to 90 percent for a permanent one. That is a tightening target: how hard to stretch the bolt at assembly. The allowable tension reported here is a capacity question: how much external axial load the bolt can carry before the chosen design factor is consumed. A bolt can be perfectly preloaded and still fail an external tension check if the applied load adds too much additional force, so both questions matter and neither substitutes for the other.

Standard practice sets preload below proof so the bolt remains elastic and returns to its original length after disassembly. AISC-style design takes a different route for ultimate limit states: Fnt = 0.75 Fu with a resistance factor φ = 0.75. Neither number is a universal allowable stress. The safety factor slider on this page lets you see how the margin moves from a generous 4.0 down to 1.5, which is the honest way to explore a load case whose magnitude is uncertain.

Where the 90 percent figure belongs

The bolt torque calculator on the homepage explains that 90 percent of yield is reserved for permanent connections with almost no reserve against over-torque. This page does not repeat that guidance; it assumes the preload decision has already been made and checks the external load that sits on top of it. Curious readers can follow the link back to the original explanation of proof versus yield.

Interaction

Combined Shear and Tension: Two Code Conventions

A bolt rarely sees a pure load. An end-plate connection under lateral load carries shear across the shank and tension from the opening moment at the same time. The two capacities are not additive: each demand consumes part of the same section, so the code checks combine their ratios rather than their forces.

AISC 360-16 §J3.7

tr + vr ≤ 1.0  (vr < 0.2)
tr + 8/9 × vr ≤ 1.0  (vr ≥ 0.2)

tr is demand divided by φRn in tension and vr is demand divided by φRn in shear. The 8/9 coefficient relaxes the linear sum once the shear ratio passes 0.2, reflecting the elliptical interaction observed in tests. Bolt design strengths use Fnt = 0.75Fu and Fnv = 0.563Fu with threads excluded from the shear plane, or 0.45Fu when threads cross it.

EN 1993-1-8 clause 3.6

Fv,Ed/Fv,Rd + Ft,Ed/(1.4 Ft,Rd) ≤ 1.0

Eurocode 3 divides tensile design resistance by an additional 1.4 in the interaction term while keeping each individual check at its own limit. Ft,Rd = 0.9 fub As / γM2 and Fv,Rd = αv fub As / γM2, with αv = 0.6 for classes 4.6, 5.6 and 8.8, and 0.5 for 4.8, 5.8, 6.8 and 10.9.

The two conventions are not interchangeable, and neither produces a single universal answer. On the default M12 8.8 example the AISC ratio is about 0.965 while the Eurocode ratio is about 0.752: both pass, but AISC is visibly closer to the limit. Slip-critical connections add a separate serviceability check that is outside this tool. Always identify the governing specification for the project before using either ratio as an acceptance criterion.

Moment, Bolt Groups and the Extra Tension Term

The moment tension share input exists because overturning is a common way for a bolt to pick up axial load without anyone typing a tensile force. For a bolt group rotating about its centroid under a moment M, the elastic distribution assigns Fi = M × yi / Σ(yj²) to bolt i, where yi is the perpendicular distance from the centroid. The outermost bolt in the tension zone carries the largest increment and is normally the one to check.

The elastic method assumes the connected plate is rigid and every bolt shares rotation proportionally to its distance. Real end plates bend. That bending adds prying force to the bolt tension, so an elastic distribution is a lower bound for an flexible plate connection. A stiffened end plate or a thicker flange reduces the gap; a thin unstiffened plate can raise bolt tension well above the simple calculation. Treat the number entered here as the distributed component only.

Compression in the contact region usually carries the opposite side of the moment, so not every bolt in the group is in tension. Which bolts separate depends on the contact model. The bolt group calculator on this site handles in-plane eccentric shear distribution, which is a different task; use it for the shear side and bring the worst-bolt result here if that bolt also sees axial pull. For a group of n identical bolts sharing a direct axial load evenly, dividing by n before checking is correct only when the load passes through the group centroid.

Sign convention. Add the moment share to direct tension when the moment tends to open the joint at that bolt. If the bolt is on the compression side of a moment-resisting connection it may see no tension at all from that component. Entering a negative number subtracts from the demand, but the tool does not decide the contact state for you.

Failure Modes in Bolt Tension

A tension check that only reports a utilization ratio hides how the joint would actually fail. The following modes are worth walking through before accepting a PASS result, because several of them are not captured by Fu × As at all.

Thread stripping in the nut or tapped hole

If the nut or the tapped material is weaker than the bolt, the threads shear before the bolt ruptures. Steel nuts sized to the bolt normally prevent this; aluminium, cast iron and thin-wall tapped parts do not. A short engagement length can strip at well below the bolt's ultimate tension. The thread engagement calculator on this site compares stripping force with bolt fracture and returns the minimum engagement length.

Tensile rupture through the stress area

This is the mode the ultimate tension capacity represents. It presents as a clean break across several thread turns near the first exposed root, usually after visible necking in a ductile grade. High-strength grades show less elongation before rupture, which is why code caps their usable strength rather than simply rewarding the higher Fu.

Over-tensioning during assembly

A bolt tightened past proof can take permanent set even before any service load arrives. The result is a relaxed joint with lost preload and a bolt that may already be work-hardened. This is the failure mode behind the homepage's 75 percent preload target, and it is independent of the external-load utilization computed here.

Prying-driven overload in end plates

A flexible plate rotates around the bolt line and adds a prying lever to the bolt force. The bolt can exceed its tension capacity while the applied moment looks modest on paper. Stiffeners, heavier plates and shorter bolt gauges all reduce the amplification.

Fatigue and hydrogen embrittlement

Cyclic tension concentrates stress at the first engaged thread root, where fatigue cracks initiate far below static capacity. High-strength grades can also suffer hydrogen embrittlement, particularly when galvanized; ASTM A490 fasteners must not be galvanized. Neither mechanism is a static capacity problem, so a PASS here is not a fatigue endorsement.

Tensile Capacity by Diameter and Grade

Ultimate tension Fu × As for common sizes, computed from the same stress-area functions the calculator uses. Metric values are in kN; unified values are in kips. These are raw rupture capacities with no safety factor applied. Select a different grade in the calculator to regenerate any row.

Metric sizeAs (mm²)Class 4.6 (kN)Class 8.8 (kN)Class 10.9 (kN)
M836.614.629.338.1
M1058.023.246.460.3
M1284.333.767.487.6
M16156.762.7125.3162.9
M20244.897.9195.8254.6
M24352.5141.0282.0366.6
Unified sizeAs (mm²)SAE Gr 2 (kip)A325 / Gr 5 (kip)A490 (kip)
1/2"91.510.517.024.1
5/8"145.816.727.138.4
3/4"215.824.840.156.9
1"390.844.872.7103.0
1-1/8"492.456.591.6129.8

Stress areas follow the ISO 68-1 and ASME B1.1 basic thread forms published on the site's thread pitch and stress area chart. Grade strengths follow ISO 898-1, SAE J429 and ASTM A307/A325/A490 as implemented in the site's shared bolt data. Values are minimum-specification rupture capacities for preliminary comparison, not code design strengths.

Worked Example: M12 Class 8.8 With a Moment Share

A bracket applies 20 kN of direct axial pull and an overturning moment that distributes 6 kN to the critical bolt. The bolt is M12 coarse in class 8.8, with a 12 kN shear component and a design factor of 2.0. The stress area is 84.27 mm², ultimate tension is 67.4 kN and allowable tension is 33.7 kN. Demand is 26 kN, so utilization is 77.1 percent with 7.7 kN of remaining margin.

The combined check is closer than the pure tension check. AISC-style design strengths are 37.9 kN in tension and 38.2 kN in shear on the shank with threads excluded, giving tr = 0.686 and vr = 0.314. Since vr is above the 0.2 threshold, the interaction is 0.686 + 0.889 × 0.314 = 0.965. The joint passes, but only just; raising shear to 15 kN pushes the interaction above 1.0 while the pure tension utilization stays below 80 percent. That is precisely why the combined check is not optional when both directions are present.

If the same connection used class 10.9, the higher Fu would lift ultimate tension and improve both ratios. If the shear plane crossed the threads instead, the AISC shear coefficient would drop from 0.563Fu to 0.45Fu and the interaction would rise. Both changes are visible immediately in the calculator, which is the point of exposing every intermediate value rather than printing a single verdict.

Tension Side, Sizing Side, Shear Side

This bolt tension calculator checks the capacity of a bolt you already have. To choose a diameter from a known load, start with the bolt size calculator. For shear stress alone, use the bolt shear calculator. For the stress areas behind every number here, see the thread pitch and stress area chart. All of these tools start from the homepage torque calculator and are listed together on the all calculators page.

FAQ

Bolt Tension FAQ

Formulas, capacities, interaction checks and the boundary with the site's other tools.

What is a bolt tension calculator?
A bolt tension calculator answers a different question from a torque calculator or a bolt size calculator: given a bolt you already have and the axial load it must carry, how much tensile capacity does it have and how close is it to the limit? It takes the diameter and thread series, the grade, the external tension and any extra tension from a moment, then reports the tensile stress area, ultimate and allowable tension, utilization, and a PASS/FAIL margin. Switch on the optional shear input and it also reports the combined shear-and-tension interaction ratio.
What is the bolt tension formula?
Axial tension capacity starts with the tensile stress area: As = 0.7854 × (d − 0.9382 × p)² for metric threads and As = 0.7854 × (D − 0.9743/n)² for unified threads. The ultimate tensile capacity is Fu × As, where Fu is the grade's minimum ultimate tensile strength. A working allowable tension is Fu × As / SF. The applied demand per bolt is the external tension plus the moment-induced share, divided by the number of bolts sharing it. Utilization is demand divided by allowable; anything above 100% fails.
What is the tension capacity of a bolt and why is it below the shank strength?
The tension capacity of a bolt is the force that would rupture it in direct axial pull, taken as Fu × As. It is below the shank's Fu × (πd²/4) because a threaded bar does not break across a flat root circle: it fails along the helical path between pitch and minor diameters. The stress area As reproduces that effective section, running roughly 78–88% of the nominal circle for coarse series. Using the shank area instead overstates tension capacity by about 15–25%, which is why every strength check on this site uses As.
What is the A325 bolt tension capacity?
ASTM A325 (now ASTM F3125 Grade A325) has a specified minimum ultimate tensile strength of 120 ksi (827 MPa) for diameters up to 1 inch and 115 ksi above that. Multiply that Fu by the tensile stress area of the size in question. A 3/4-10 UNC bolt has As ≈ 0.334 in², giving about 40 kips of ultimate tension before any safety factor. AISC design tensile strength uses Fnt = 0.75 Fu with φ = 0.75; this tool reports both the raw Fu × As capacity and an allowable value at the safety factor you choose.
What is the allowable tension in bolts?
Allowable tension is the working force you permit after dividing the bolt's capacity by a design factor. Two conventions are common: a working-stress value Fu × As / SF, and a code value such as AISC's φRn = 0.75 × (0.75 Fu) × Ab. The homepage's preload guidance uses 75% of proof or yield as a target for reusable joints and up to 90% for permanent ones; that is a tightening target, not the same thing as the external-load capacity reported here. Use this page for applied load margin, and the homepage for how hard to tighten.
How do I check combined shear and tension in a bolt?
Run both checks separately, then combine the ratios. Under EN 1993-1-8 the interaction is Fv,Ed/Fv,Rd + Ft,Ed/(1.4 × Ft,Rd) ≤ 1.0, with Ft,Rd = 0.9 fub As / γM2. AISC 360-16 §J3.7 uses a piecewise interaction between the tension ratio and the shear ratio, with a reduced shear coefficient once the shear ratio exceeds 0.2. This calculator reports both ratios so you can see which code governs your case. It is a preliminary check only: slip-critical connections, prying and fatigue require the governing specification.
How do I calculate tension in bolts due to a moment?
For a bolt group rotated by an overturning moment M about its centroid, elastic distribution gives the additional tensile force in bolt i as Fi = M × yi / Σ(yj²), where yi is the distance from the group centroid to that bolt measured perpendicular to the moment axis. The farthest bolt picks up the largest share. Add that share to the direct axial tension before comparing with capacity. Note that a real end-plate connection also develops prying forces, so a pure elastic distribution is a lower bound unless the plate stiffness is included.
Is a bolt stronger in tension or in shear?
On nominal material properties, a bolt is usually stronger in axial tension than in single shear. Tension uses the stress area As with the full ultimate strength Fu, while AISC-style shear uses roughly 0.563 Fu (threads excluded) or 0.45 Fu (threads included) on the shank area. A double-shear connection, with two planes sharing the load, can approach or exceed the tension capacity. The answer also depends on the connection: bearing, tear-out and block shear in the plates often govern before the bolt itself does.

Sources and scope. Stress area: ISO 68-1 and ASME B1.1 basic 60° thread form, via AISC 360-16 and the site's thread pitch chart. Grade strengths: ISO 898-1, SAE J429, ASTM A307/A325/A490. Combined action: AISC 360-16 §J3.7 and EN 1993-1-8 clause 3.6 / Table 3.4. Code interaction coefficients are reproduced from published code summaries and must be confirmed against the governing specification text before production use.

Author & update. Bolt Calculatorengineering content team · Last updated 2026-11-23 · Data current to 2026-11-23. This page is preliminary engineering reference, not a substitute for design review or a licensed professional's approval.